Gocator Line Profile Sensors: User Manual
Gocator Device Files • 403
Element Type Description
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
PreserveInvalidsEnabled Boolean Preserve invalid measurements enable state
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
ProfileRoundCorner
A ProfileRoundCorner element defines settings for a profile round corner tool and one or more of its
measurements.
Element Type Description
Name String Tool name.
Features
Collection Not used.
Source 32s Profile source.
Anchor\X String (CSV) The X measurements (IDs) used for anchoring.
Anchor\X.options String (CSV) The X measurements (IDs) available for anchoring.
Anchor\Z String (CSV) The Z measurements (IDs) used for anchoring.
Anchor\Z.options String (CSV) The Z measurements (IDs) available for anchoring.
StreamOptions Collection
A collection of StreamOptions on page 382 elements.
Stream\Step
32s The stream source step. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
ProfileRoundCorner Child Elements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2140 and is the answer not in the manual?

LMI Technologies Gocator 2140 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2140
CategoryAccessories
LanguageEnglish

Related product manuals