Field Type Offset Description
Bits 0-14: Message type identifier. For this message, set to 5.
attributeSize 16u 6 Size of attributes, in bytes (min: 32, current: 32).
count (C) 32u 8 Number of profile arrays.
width (W) 32u 12 Number of points per profile array.
xScale 32u 16 X scale (nm).
zScale 32u 20 Z scale (nm).
xOffset 32s 24 X offset (µm).
zOffset 32s 28 Z offset (µm).
Source 8u 32 Source
0 – Top
1 – Bottom
2 – Top Left
3 – Top Right
exposure 32u 33 Exposure (ns).
cameraIndex 8u 37
Camera index.
reserved[2] 8u 38 Reserved.
ranges[C][W] Point16s 40 Profile ranges.
Resampled Profile
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 6.
attributeSize 16u 6 Size of attributes, in bytes (min: 32, current: 40).
count (C) 32u 8 Number of profile arrays.
width (W) 32u 12 Number of points per profile array.
xScale 32u 16 X scale (nm).
zScale 32u 20 Z scale (nm).
xOffset 32s 24 X offset (µm).
zOffset 32s 28 Z offset (µm).
source 8u 32 Source
0 – Top
1 – Bottom
2 – Top Left
3 – Top Right

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 100 and is the answer not in the manual?

LMI Technologies Master 100 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 100
CategoryAccessories
LanguageEnglish

Related product manuals