Chapter 7 Exclusive Functions for iS7 Inverter Control/Monitoring
7-2
Symbol Name Description
J3
NPN/PNP Selection
Jumper
1) NPN mode: connects terminal block input (P00~P05) and 24G.
for details, see page 7-5.
2) PNP mode: connects terminal block input (P00~P05) and 24P.
for details, see page 7-5.
CON1
RS232C
Communication
Connector
Connector for connection with KGLWIN
Battery
Battery Housing
1) Function: in case of power failure, maintain the data of the latch
area of PLC option and RTC time data.
2) Battery type: coin-type lithium ion battery (CR2032)
3) Service life: approx. 4 years in power-off state (at room
temperature, battery capacity 220mAh)
1: S+(RS485) 2: S-(RS485)
3: 24G 4: Terminal input P00
5: Terminal input P01 6: Terminal input P02
7: Terminal input P03 8: Terminal input P04
9: Terminal input P05 10: 24G
11: 24P (external 24V output) -
12: Terminal output P40 13: Terminal output P40C
14: Terminal output P41 15: Terminal output P41C
16: Terminal output P42 17: Terminal output P42C
TB1
External Terminal
Block
18: Terminal output P43 19: Terminal output P43C
Detail outline of the external terminal block (TB1) is shown below.
RS485 (+) 단자 : Modbus-RTU 마스
RS485 (-) 단자 : Modbus-RTU 마스
24GND
24GND
24V 출력
Terminal
input acts
as NPN.
Terminal
input acts
as PNP.
4 TB outputs
RS485 (-) Terminal : Modbus RTU
RS485 (+) Terminal : Modbus RTU
6 TB outputs