Code
Comm.
Address
Name
Setting Range
Initial
Value
Property
*
V/
F
S
L
Ref.
bA-83
8
0h1253
Multi-step
deceleration
time 7
0.0600.0 (s)
20.0
O
O
O
p.80
8.4 Expanded Function Group (PAR→Ad)
In the following table, data shaded in grey will be displayed when the related code has
been selected.
SL: Sensorless vector control (dr.09), Property: Write-enabled during operation
Code
Comm.
Address
Name
Setting
Range
Initial
Value
Property*
V/F
SL
Ref.
Ad-00
-
Jump Code
199
24
O
O
O
p.42
Ad-01
0h1301
Acceleration
pattern
0
Linear
0: Linear
X
O
O
p.83
Ad-02
0h1302
Deceleration
pattern
1
S-curve
X
O
O
p.83
Ad-03
9
0h1303
S-curve
acceleration
start point
gradient
1100 (%)
40
X
O
O
p.83
Ad-04
9
0h1304
S-curve
acceleration
end point
gradient
1100 (%)
40
X
O
O
p.83
Ad-05
10
0h1305
S-curve
deceleration
start point
gradient
1100 (%)
40
X
O
O
p.83
Ad-06
10
0h1306
S-curve
deceleration
end point
gradient
1100 (%)
40
X
O
O
p.83
Ad-07
0h1307
Start Mode
0
Acc
0: Acc
X
O
O
p.92
1
Dc-Start
Ad-08
0h1308
Stop Mode
0
Dec
0: Dec
X
O
O
p.94
1
Dc-Brake
9