Page #255 background imageLoading...
Page #255 background image
Code
Comm.
Address
Name
Keypad
Display
Setting
Range
Initial
Value
Property*
V/F
SL
Ref.
frequency 2
frequency
(Hz)
-
0h1D07
Multi-step
speed
frequency 3
St3
0.00
Maximum
frequency
(Hz)
30.00
O
O
O
p.71
-
0h1D08
Output
current
CUr
-
-
-
O
O
p.53
-
0h1D09
Motor
revolutions
per minute
Rpm
-
-
-
O
O
-
-
0h1D0A
Inverter DC
voltage
dCL
-
-
-
O
O
p.53
-
0h1D0B
Inverter
output
voltage
vOL
-
-
-
O
O
p.53
-
0h1D0C
Out of order
signal
nOn
-
-
-
O
O
-
-
0h1D0D
Select
rotation
direction
drC
F
Forward
direction
operation
F
O
O
O
-
r
Reverse
run
8.2 Drive Group (PAR→dr)
In the following table, data shaded in grey will be displayed when the related code has
been selected.
SL: Sensorless vector control (dr.09), Property: Write-enabled during operation
Cod
e
Comm.
Addres
s
Name
Setting Range
Initial
Value
Property
*
V/
F
S
L
Ref.
dr-00
-
Jump Code
199
9
O
O
O
p.42
dr-09
0h1109
Control
mode
0
V/F
0: V/F
X
O
O
p.85,
p.122
,
p.134
2
Slip Compen
4
IM Sensorless
dr-11
0h110B
Jog
Frequency
0.00, Start
frequency
Maximum frequency
(Hz)
10.00
O
O
O
p.114