EasyManuals Logo

LSIS LSLV-G100 User Manual

LSIS LSLV-G100
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #256 background imageLoading...
Page #256 background image
Cod
e
Comm.
Addres
s
Name
Setting Range
Initial
Value
Property
*
V/
F
S
L
Ref.
dr-12
0h110C
Jog run
acceleration
time
0.0600.0 (s)
20.0
O
O
O
p.114
dr-13
0h110D
Jog run
deceleration
time
0.0600.0 (s)
30.0
O
O
O
p.114
dr-14
0h110E
Motor
capacity
0: 0.2 kW
1: 0.4 kW
2: 0.75 kW
3: 1.1 kW
4: 1.5 kW
5: 2.2 kW
6: 3.0 kW
7: 3.7 kW
8: 4.0 kW
9: 5.5 kW
10: 7.5 kW
11: 11.0 kW
Varies by
Motor
capacity
X
O
O
p.131
dr-15
0h110F
Torque
boost mode
0
Manual
0:
Manual
X
O
X
p.90
1
Auto
dr-16
0h1110
Forward
Torque
boost
0.015.0 (%)
2.0
X
O
X
p.90
dr-17
0h1111
Reverse
torque boost
0.015.0 (%)
2.0
X
O
X
p.90
dr-18
0h1112
Base
frequency
30.00400.00 (Hz)
[V/F, Slip Compen]
40.00120.00 (Hz)
[IM Sensorless]
60.00
X
O
O
p.85
dr-19
0h1113
Start
frequency
0.0110.00 (Hz)
0.50
X
O
O
p.85
dr-20
0h1114
Maximum
frequency
40.00400.00 (Hz)
[V/F, Slip Compen]
40.00120.00 (Hz)
[IM Sensorless]
60.00
X
O
O
p.98
dr-
26
2
0h111 A
Auto torque
boost filter
gain
11000
2
O
O
X
2