11.2 Product Specification Details
V/F control, slip compensation, sensorless vector
Frequency
settings power
resolution
Analog command: 0.06 Hz (60 Hz standard)
1% of maximum output frequency
Linear, square reduction, user V/F
Heavy load rated current: 150%, 1 minute,
Light load rated current: 120%, 1minute
Manual torque boost, automatic torque boost
Select key pad, terminal strip, or communication
operation
Analog type: -10–10 V, 0–10 V, 4–20 mA
• 3-Wire Operation
• Frequency limit
• Second motor function
• Anti-forward and reverse
direction rotation
• Commercial transition
• Speed search
• Power braking
• Up-down operation
• Frequency jump
• Slip compensation
• Automatic restart
• Auto tuning
• Energy buffering
• Flux braking
• Fire Mode
Multi-
function
terminal
(5EA)
Select PNP (Source) or NPN (Sink) mode.
Functions can be set according to In.65– In.69 codes
and parameter settings.
• Forward direction
operation
• Reset
• Emergency stop
• Multi step speed
frequency-high/med/low
• DC braking during stop
• Frequency increase
• 3-wire
• Select acc/dec/stop
• External trip
• Jog operation
• Multi step acc/dec-
high/med/low
• Second motor selection
• Frequency reduction
• Fix analog command
frequency
• Transition from PID to
general operation