T3 (LTP parameters jump without time; channels & pan, tilt and dimmer parameters fade at time,
and also size and rate for shapes).
Autoscroll: If ENABLE, console searches” channels and fixtures in the edition process
Load Grp Num: Sets the ranges of recording of groups with [LOAD]
Double Cue N: Sets the ranges of recording of cues in Double mode
Virtual dm: Uses the virtual dimmer in edition for fixtures of color mix without dimmer (i.e.
LEDs fixtures, see COMMANDS FOR FIXTURES, in page-34)
Lib rec Mode: Only for Piccolo Scan. Sets that parameters are stored in each library (all of
the category or only selected parameters)
Chans->CH-MD: To select the channels number with access over the C potentiometers;
controlling the banks number in [CH.ND].
37.4.2. Playbacks (31)
For Playbacks configuration:
Level for Flash, normal, solo or absolute (Flash Level)
If Solo Flash affects to the crossfader output, or not (Solo Off X)
Configurations for the general faders: SM, GM and their back-out keys (SM, GM, BLKoUT-SM)
Dipless Crossfader Formula: (Dipless Mode). These formulas affect to the channels in X2
that they have a lower level that the current scene level, in one formula, these channels can fade as
input channels (T ) or as in scene fade out can fade as output channels (T).
The option Return track, where:
Return Track is ENABLED: when a group, or cue, is deactivated from a
Submaster, its “ltp” parameters (all the fixture parameters except dimmer) return to their
initial value with their corresponding fading. In general, if you are storing colors,
dimmers, positions, etc. in several submasters, and then you combine them, uses this option.
Return Track is DISABLED: when a group, or cue, is deactivated from a
Submaster, its “ltp” parameters (all the fixture parameters except dimmer) remain in scene
until Submaster has reached its 0%. And if any playback is no controlling them, these will
maintain its values in scene as new tracking. In general, if you are storing complete
scenes, with dimmer and parameters in the same Submaster, uses this option.
We made one example to understand the difference.
Store in S1 a group with a Scroller in red and in S2, the same Scroller in green. And, we
observe the differences, activating and deactivating the Submasters in different sequences:
Submasters
Color in Scene
ENABLED
DISABLED
We begin with Home
White (initial tracking)
White (initial tracking)