- Command header and error check data is not available.
- Include texts to UDP packet data and send it to WeiverEx.(Each character size is 2-byte)
- Ports from 50400 and 50500 are selectable from WeiverEx’
- WeiverEx’ responses back to the port that server used sending such data.
- CANNOT process multiple number of commands repeatedly.
- Two ‘UDP Event’ commands are available, ‘set_eventle and get_eventle.
1) set_eventle event description
- Must have spaces between the set_eventle and event description.
- Event Description: is one that goes into ‘lename.wev, maximum text up to 99. do NOT use
comma( , ).
2) “set_eventle
- Basic event description if specic event description is not available.
3) “get_eventle
- Check whether the ‘Event’ has occurred or not.
4.3 / Description of UDP event during recording
- Response to set_eventle
1) If successful : ok(event description)
2) If failed :
“fail(invalid state)”
“fail(event overlap)”
- Response to get_eventle
1) If successful : ok(event description)”
2) If failed : “fail(invalid le)”
- Response to set_eventle and get_eventle’
“fail(invalid command)”