Luminex 200 Installation Manual
8
Figure 10. Barcode Reader Laser Label
Mechanical
Biological
Heat
Blue Indicator Light
The blue light above the Luminex 200 analyzer sample arm indicates
the on/off status of the analyzer; it is harmless. The blue light-
emitting diode (LED) does not emit light in the UV spectrum.
Warning: During operation, this system contains exposed, mov-
ing parts. Risk of personal injury is present. Observe all warnings
and cautions.
Warning: During operation, this system contains exposed, mov-
ing parts which could result in puncture hazard. Risk of personal
injury is present. Keep hands and fingers away from the Luminex
XYP instrument slot during operation.
Warning: During operation, this system contains exposed, mov-
ing parts which could result in pinch point hazard. Risk of per-
sonal injury is present. Keep hands and fingers away from the
Luminex XYP instrument slot during operation.
Note: Access doors must be
closed while operating the
Luminex 200 analyzer; the
operator must be present
during operation.
Warning: Human and animal samples may contain biohazardous
infectious agents. Where exposure (including aerosol) to potentially
biohazardous material exists, follow appropriate biosafety proce-
dures and use personal protective equipment, such as gloves, gowns,
laboratory coats, face shields, or mask and eye protection, and venti-
lation devices.
Observe all local, state, and federal biohazard handling regulations
when disposing of biohazardous waste material.
Warning: The heater plate of the Luminex XYP instrument may be
hot and could cause personal injury if touched. Do not touch the
heater plate.

Other manuals for Luminex 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Luminex 200 and is the answer not in the manual?

Luminex 200 Specifications

General IconGeneral
Power Requirements100-240 VAC, 50/60 Hz
Dynamic Range3.5 logs
Number of AnalytesUp to 100
SoftwarexPONENT
ApplicationImmunoassays, Nucleic Acid Detection, Enzyme Assays
TechnologyxMAP (Multi-Analyte Profiling)
Bead TypesColor-coded microspheres
Lasers2 (532 nm and 635 nm)
Assay TypesImmunoassays, nucleic acid assays, enzyme assays
Sample Volume12.5 - 50 µL
PMT DetectorsYes