Do you have a question about the Luminex 200 and is the answer not in the manual?
Defines the intended purpose and application of the Luminex 200 Instrument in multiplex testing.
Provides essential safety information for setting up and using the Luminex 200 analyzer.
Addresses safety concerns related to the fluidics system and potential fluid leaks.
Classifies the Luminex 200 instrument's laser components and provides safety information.
Outlines warnings and precautions related to exposed moving parts and potential injury hazards.
Warns about potential biohazardous materials in samples and necessary safety procedures.
Provides a checklist and instructions for decontaminating the Luminex 200 analyzer before shipping.
Explains the principles of Luminex xMAP technology and the instrument's operational flow.
Outlines daily procedures for system upkeep, including startup and cleaning steps.
Details weekly checks and cleaning procedures like visual inspection and probe cleaning.
Describes monthly tasks including cleaning exterior surfaces and system calibration.
Introduces troubleshooting procedures for the Luminex 200 analyzer and XYP instrument.
Guides users through diagnosing and resolving issues related to power supply and fuses.
Addresses issues with low or high system pressure and potential causes.
Guides users on identifying and resolving fluid leaks within the system.
Provides solutions for problems related to the sample probe, including leaks and movement.
Helps troubleshoot issues encountered during calibration and control runs.
Addresses common issues that cause acquisition failures or slow performance.
Defines the intended purpose and application of the Luminex 200 Instrument in multiplex testing.
Provides essential safety information for setting up and using the Luminex 200 analyzer.
Addresses safety concerns related to the fluidics system and potential fluid leaks.
Classifies the Luminex 200 instrument's laser components and provides safety information.
Outlines warnings and precautions related to exposed moving parts and potential injury hazards.
Warns about potential biohazardous materials in samples and necessary safety procedures.
Provides a checklist and instructions for decontaminating the Luminex 200 analyzer before shipping.
Explains the principles of Luminex xMAP technology and the instrument's operational flow.
Outlines daily procedures for system upkeep, including startup and cleaning steps.
Details weekly checks and cleaning procedures like visual inspection and probe cleaning.
Describes monthly tasks including cleaning exterior surfaces and system calibration.
Introduces troubleshooting procedures for the Luminex 200 analyzer and XYP instrument.
Guides users through diagnosing and resolving issues related to power supply and fuses.
Addresses issues with low or high system pressure and potential causes.
Guides users on identifying and resolving fluid leaks within the system.
Provides solutions for problems related to the sample probe, including leaks and movement.
Helps troubleshoot issues encountered during calibration and control runs.
Addresses common issues that cause acquisition failures or slow performance.
| Power Requirements | 100-240 VAC, 50/60 Hz |
|---|---|
| Dynamic Range | 3.5 logs |
| Number of Analytes | Up to 100 |
| Software | xPONENT |
| Application | Immunoassays, Nucleic Acid Detection, Enzyme Assays |
| Technology | xMAP (Multi-Analyte Profiling) |
| Bead Types | Color-coded microspheres |
| Lasers | 2 (532 nm and 635 nm) |
| Assay Types | Immunoassays, nucleic acid assays, enzyme assays |
| Sample Volume | 12.5 - 50 µL |
| PMT Detectors | Yes |