xMAP Technology Safety
3
switch is not a disconnect means; power cords must be removed
from the outlet. Contact Luminex Corporation for further
information.
You must monitor waste levels manually. Do not allow the waste
container to overflow! Empty the waste container each time the
sheath fluid container is filled. Do not place the waste container on
top of the instrument. Contact Luminex Technical Support before
relocating the waste container or rerouting the waste line.
Electromagnetic
Compatibility
The Luminex 200 system complies with the emission and immunity
requirements described in EN 61326-1 and EN 61236-2-6. The
electromagnetic environment should be evaluated prior to operation.
Warning: Do not use this device in close proximity to sources of
strong electromagnetic radiation, for example, unshielded intentional
RF sources, as these may interfere with proper operation.
Warning: Always handle the Luminex 200 system according to
Luminex instructions to avoid any possible interference from its
electromagnetic fields.
Luminex 200 Analyzer
Laser
The Luminex 200 instrument is classified under FDA 21 CFR
1040.10 and 1040.11 as a Class I laser product consisting of two
Class IIIb lasers within the instrument. The accessory bar code
reader is classified as Class II. In accordance with IEC 60825-1, the
instrument is classified as Class 1, containing two Class 3b lasers,
and including an accessory Class 2 bar code reader. The Luminex
200 complies with IEC 60825-1 and 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice No. 50, dated June 24,
2007.
Warning: If biological samples have been tested with the system,
use your standard laboratory safety practices when handling
system waste.

Table of Contents

Other manuals for Luminex 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Luminex 200 and is the answer not in the manual?

Luminex 200 Specifications

General IconGeneral
Power Requirements100-240 VAC, 50/60 Hz
Dynamic Range3.5 logs
Number of AnalytesUp to 100
SoftwarexPONENT
ApplicationImmunoassays, Nucleic Acid Detection, Enzyme Assays
TechnologyxMAP (Multi-Analyte Profiling)
Bead TypesColor-coded microspheres
Lasers2 (532 nm and 635 nm)
Assay TypesImmunoassays, nucleic acid assays, enzyme assays
Sample Volume12.5 - 50 µL
PMT DetectorsYes