KEYPAD KP200
2 Parameter list
2-6
214 FIE00 Function selector digital input IED00 (user module) OFF OFF, STR, STL, INV, /STOP,
SADD1, SADD2, E-EXT, RSERR,
MP-UP, MP-DN, CUSEL, FFTB0,
FFTB1, FFTB2, UM0, UM1, /LCW,
/LCCW, SIO, OPTN1, OPTN2,
USER0, USER1, USER2, USER3,
MAN
SADD2 = Change-over reference selec-
tor 281-RSSL2 with value of 290-
SADD2
E-EXT = External error
RSERR = Reset error
MP-UP = Motor poti, increase refe-
rence
MP-DN = Motor poti, decrease refe-
rence
CUSEL = CDS characteristic data set
switchover
FFTB0 = Fixed frequency selector 2
0
FFTB1 = Fixed frequency selector 2
1
FFTB2 = Fixed frequency selector 2
2
UM0 = UDS switchover 2
0
UM1 = UDS switchover 2
1
/LCW = Limit switch clockwise
/LCCW = Limit switch counterclock-
wise
SIO = via SIO status word
OPTNx = for option module 1/2
USERx = reserved for special software
MAN = Manual mode (bus operation)
ENC = Encoder input
FMSI = Reference coupling (M-S)
INCLK = Clock reference input
33
215 FIE01 Function selector digital input IED01 (user module) OFF 33
216 FIE02 Function selector digital input IED02 (user module) OFF 33
217 FIE03 Function selector digital input IED03 (user module) OFF 33
218 FIE04 Function selector digital input IED04 (user module) OFF 33
219 FIE05 Function selector digital input IED05 (user module) OFF 33
220 FIE06 Function selector digital input IED06 (user module) OFF 33
221 FIE07 Function selector digital input IED07 (user module) OFF 33
222 FIF0 Function selector virtual fixed input 0 OFF
OFF, STR, STL, INV, /STOP,
SADD1, SADD2
siehe 210-FIS00 4 4
223 FIF1 Function selector virtual fixed input 1 OFF 44
no. name unit function factory set your set range of value explanation R W