KEYPAD KP200
2  Parameter list
2-5
_21ID Digital inputs 
210 FIS00 Function selector digital standard input ISD00 STR OFF, STR, STL, INV, /STOP, 
SADD1, SADD2, E-EXT, RSERR, 
MP-UP, MP-DN, CUSEL, FFTB0, 
FFTB1, FFTB2, UM0, UM1, /LCW, 
/LCCW, SIO, OPTN1, OPTN2, 
USER0, USER1, USER2, USER3, 
MAN, ENC, FMSI, INCLK
OFF = switched off
STR = Start clockwise rotation
STL = Start counter-clockwise
INV = Invert direction of rotation
/STOP = Stop ramp 
SADD1 = Change-over reference selec-
tor 280-RSSL1 with value of 289-
SADD1
12
211 FIS01 Function selector digital standard input ISD01 STL 12
212 FIS02 Function selector digital standard input ISD02 SADD1 12
213 FIS03 Function selector digital standard input ISD03 OFF 12
no. name   unit function factory set your set range of value explanation R W