Sivoia® QS roller 64TM Dual Mount Installation instructions
Page 7
5
Wire 4-Pin terminal block
5.1
Strip 2 in. (50 mm)
of jacket off the
cables that run
from the wall.
Wire 4-Pin terminal block (provided) to cable using the included screwdriver. Make sure to tighten the screws
tightly and that no insulation is inside of the terminal block.
Note: The EDU connector will support wire sizes from AWG 12 (2.5 mm
2
) to AWG 26 (0.2 mm
2
).
See the instruction sheet for your power supply to choose an appropriate wire size for your application.
Note: Strip insulation from wires so that 0.25 in. (6.3 mm) of bare wire is exposed.
5.2
To EDU
Connector
MUX (Pin 4)
MUX (Pin 3)
24 V (Pin 2)
Common (Pin 1)
}