EasyManua.ls Logo

MacDon M105 - Page 38

MacDon M105
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNLOADING AND ASSEMBLY
169558 36 Revision D
L1 C
x
x
x
||
DISPL
A
Y
UN I TS?
L2 M
x
x
x
||
IMPERI
A
L
L2 M
x
x
x
||
METRIC
L1 C
x
x
x
||
BU
Z
Z
ER
V
OLUME
L2 M
x
x
x
||
L1 C
x
x
x
||
B
A
CKLIGHTING
L2 M
x
x
x
||
L1 C
x
x
x
||
DISPL
A
Y
CONTR
A
ST
L2 M
x
x
x
||
L1 C
x
x
x
||
EX I T D I SPL
A
Y
SETUP?
L2 M
x
x
x
||
NO /
Y
ES D I SPL
A
Y
L
A
NGU
A
GE?
L1 C
x
x
x
||
C
A
LIBR
A
TE SENSORS?
L2 M
x
x
x
||
NO /
Y
ES D I
A
GNOST I C MODE?
L1 C
x
x
x
||
TO C
A
LIBR
A
TE SELECT
L2 M
x
x
x
||
HE
A
DER HE IGHT
L2 M
x
x
x
||
HE
A
DER T I LT
L2 M
x
x
x
||
STOP & E
X
IT
L1 C
x
x
x
||
HE IGHT SENSOR C
A
L
L2 M
x
x
x
||
R
A
ISE HDR TO ST
A
RT
L1 C
x
x
x
||
C
A
LIBR
A
TING HEIGHT
L2 M
x
x
x
||
R
A
ISE HE
A
DER HOLD
L2 M
x
x
x
||
R
A
ISE HE
A
DER DONE
L1 C
x
x
x
||
HE IGHT SENSOR C
A
L
L2 M
x
x
x
||
PRESS LO
W
ER HE
A
DER
L1 M
x
x
x
||
C
A
LIBR
A
TING HEIGHT
L2 M
x
x
x
||
LO
W
ER HE
A
DER HOLD
L2 M
x
x
x
||
HT SENSOR COMPLETE
L1 C
x
x
x
||
TO C
A
LIBR
A
TE SELECT
L2 M
x
x
x
||
HE
A
DER HE IGHT
L1 C
x
x
x
||
TO C
A
LIBR
A
TE SELECT
L2 M
x
x
x
||
HE
A
DER HE IGHT
L2 M
x
x
x
||
HE
A
DER T I LT
L1 M
x
x
x
||
HDR T I LT SENSOR C
A
L
L2 M
x
x
x
||
EXTEND TLT TO ST
A
RT
L1 C
x
x
x
||
C
A
LIBR
A
TING TILT
L2 M
x
x
x
||
EXTEND T I LT HOLD
L2 M
x
x
x
||
EXTEND T I LT DONE
L1 M
x
x
x
||
HDR T I LT SENSOR C
A
L
L2 M
x
x
x
||
PRESS RETR
A
CT T I LT
L1 C
x
x
x
||
C
A
LIBR
A
TING TILT
L2 M
x
x
x
||
RETR
A
CT T I LT HOLD
L2 M
x
x
x
||
HDR T ILT COMPLETE
L1 C
x
x
x
||
TO C
A
LIBR
A
TE SELECT
L2 M
x
x
x
||
HE
A
DER T I LT
L2 M
x
x
x
||
STOP & E
X
IT
L1 C
x
x
x
||
EX I T C
A
LIBR
A
TION?
L2 M
x
x
x
||
NO /
Y
ES TO C
A
LIBR
A
TE SELECT
If the HEADER TILT option in the WINDROWER
SETUP is set to NO and/or no expansion module
then HEIGHT is only option for calibration.
The “arrow” keys are used to select between
IMPERIAL or METRIC. The default value will be
displayed first.
The menu will display the last item selected when
the calibration routine is com
p
leted.
When a function is activated, the display will
indicate the function being calibrated. HOLD will
flash until the system has completed reading in the
signal with the header fully raised.
If “NO” then
j
um
p
to:
The operator can select any of the two items
requiring calibration or to STOP & EXIT the menu.
DONE will flash and prompt the operator to
COMPLETE the sensor calibration by lowering the
header.
NOTE:
If “yes is selected and engine is not
running, system will jump to DIAGNOSTIC MODE
NOTE:
if “yes” is selected, then system
jumps to DIAGNOSTIC MODE
When sensor is displayed, press “select” to enter
calibration sequence and follow prompts on display
If “NO” then
j
um
p
to:
If “NO” then
j
um
p
to:
The “arrow keys are used to change the CDM
buzzer volume, CDM backlighting or the CDM
contrast, with the bar graph indicating the relative
level for each item. When “SELECT” is pressed
the program goes to the EXIT DISPLAY SETUP?
menu selection.
NOTE:
CALIBRATE SENSORS option is
only available with engine running
(continued next page)

Other manuals for MacDon M105