© 2018 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 36
Rev. Date 040218
75 ft lbs
75 ft-lbs
[102 N-m]
Use the two holes closest to
the center line of the glulam.
The bracket can be below the bottom
of the glulam if necessary but
is not recommended if it is avoidable.
2.2.1 Fixed Angle Mount Glulam
1/8" safety cable clearance
Holes can be oversized
for leveling the mount
1/2" bolt clearance
This method is recommended for Glulams or wood beams between
4-1/8” or wider. For narrower beams, span across two or more beams
using the Unistrut mounting method.