© 2018 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 69
Rev. Date 040218
Code Name
Code
Type
Factory
Setting
Description Symptoms Troubleshooting Tips
1028 Hall Error
Fan Will Not
Start
Fan Will Not
Complete Blade
Detect
Fan “Twitches”
Fan Runs
Irregularly
Conrm that hall sensor is properly
plugged into the drive
1029
Receive Frame
Error / Noise On
Comm Lines
Fan Stops
Fan Will Not
Start
1. Conrm whether touchpad was
unplugged or not
2. Conrm that CAT5 is under 100ft
3. Conrm that CAT5 is from factory and
has not been modied
4. Conrm that CAT5 is shielded
5. Conrm that repeaters are properly
installed on the network
6. Double check network splices
7. Plug touchpad directly into board
8. Conrm rmware is 146 or above
COMM
ERROR
Fan Stops
Fan Will Not
Start
1. Conrm whether touchpad was
unplugged or not
2. Conrm that CAT5 is under 100ft
3. Conrm that CAT5 is from factory and
has not been modied
4. Conrm that CAT5 is shielded
5. Conrm that repeaters are properly
installed on the network
6. Double check network splices
7. Plug touchpad directly into board
8. Test for 5VDC on blue pair if screen
lights up, test for 24VDC if screen does
not light up
Troubleshooting
For all other fault codes, please call Technical Support at (866) 668-3247.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MacroAir Technologies AirVolution-D 370 and is the answer not in the manual?

MacroAir Technologies AirVolution-D 370 Specifications

General IconGeneral
BrandMacroAir Technologies
ModelAirVolution-D 370
CategoryFan
LanguageEnglish

Related product manuals