EasyManuals Logo

Magnetek Enrange Flex EX User Manual

Magnetek Enrange Flex EX
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Flex 8EX EU System Instruction Manual
March 2012
27 of 37
6. Receiver Installation
A. Output Relay Contact Diagram
* For the 3-relay (shared 2
nd
speed) and 4-relay (separate 2
nd
speed) configuration please refer to
pages 18-22.
* For the 4-relay closed/closed and 4-relay opened/closed relay configuration please refer to
pages 18-22.
* For different voltage settings please refer to page 25.
* For F9 and F10 power fuse ratings please refer to page 25.
* For 12-24VDC power supply, wire #1 corresponds to the negative charge (-) and wire #3
corresponds to the positive charge (+). Wire #2 is for GROUND.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek Enrange Flex EX and is the answer not in the manual?

Magnetek Enrange Flex EX Specifications

General IconGeneral
BrandMagnetek
ModelEnrange Flex EX
CategoryRemote Control
LanguageEnglish

Related product manuals