Flex 8EX EU System Instruction Manual
March 2012
27 of 37
6. Receiver Installation
A. Output Relay Contact Diagram
* For the 3-relay (shared 2
nd
speed) and 4-relay (separate 2
nd
speed) configuration please refer to
pages 18-22.
* For the 4-relay closed/closed and 4-relay opened/closed relay configuration please refer to
pages 18-22.
* For different voltage settings please refer to page 25.
* For F9 and F10 power fuse ratings please refer to page 25.
* For 12-24VDC power supply, wire #1 corresponds to the negative charge (-) and wire #3
corresponds to the positive charge (+). Wire #2 is for GROUND.