Parameter Parameter Name Default Range Units Page
A01.01 Access Level 0001 0000~0001 - 42
00: User
01: Basic
02: Advanced
A01.02 Control Method 00 00, 02 - 42
00: V/f
02: OLV
A01.03 Motion 01 00, 01, 04 - 44
00: Traverse
01: Hoist
04: Braketronic
A01.04 Speed Reference 01 00–05 - 43
00: 2-Speed Multi-Step
01: 3-Speed Multi-Step
02: 5-Speed Multi-Step
03: 2-Step Infinitely Variable
04: 3-Step Infinitely Variable
05: Analog - Uni-Polar
A01.05 Initialize 0000 0000–5550 - 47
0000: No Initialize
1110: User Initialize
5550: Moves modified parameters
from terminal board to control board
A01.06 Password 1 0000 0000–9999 - 47
A01.08 Password 2 0000 0000–9999 - 47
B01.01 Frequency Reference 1 15.00* 0.00–150.00 Hz 49
B01.02 Frequency Reference 2 30.00* 0.00–150.00 Hz 49
B01.03 Frequency Reference 3 60.00* 0.00–150.00 Hz 49
B01.04 Frequency Reference 4 0.00* 0.00–150.00 Hz 49
B01.05 Frequency Reference 5 0.00* 0.00–150.00 Hz 49
B01.06 Frequency Reference 6 0.00* 0.00–150.00 Hz 49
B01.07 Frequency Reference 7 0.00* 0.00–150.00 Hz 49
B01.08 Frequency Reference 8 0.00* 0.00–150.00 Hz 49
B01.09 Frequency Reference 9 0.00* 0.00–150.00 Hz 49
B01.10 Frequency Reference 10 0.00* 0.00–150.00 Hz 49
B01.11 Frequency Reference 11 0.00* 0.00–150.00 Hz 49
B01.12 Frequency Reference 12 0.00* 0.00~150.00 Hz 49
B01.13 Frequency Reference 13 0.00* 0.00–150.00 Hz 49
B01.14 Frequency Reference 14 0.00* 0.00–150.00 Hz 49