Kebco Frequency Drive Error List
M&R Printing Equipment, Inc. - Glen Ellyn, Illinois
132
HCL
hardware current limit
80 Hardware current limit active
SrA
search for ref. active
81 Search for reference point approach active
ccd
calculate drive
82 Measurement of the motor stator resistance
POSI
positioning
83 Positioning function active
PLS
low speed/power off
84
No direction of rotation after Power-Off
bon
brake on
85
Brake control, brake engaged
boff
brake off
86
Brake control, brake released
A.OHI
ABN.STOP overheat int.
87 Warning: over temperature in the interior
A.nOH
no A. overheat pow. mod.
88 Warning: no more over temperature of power module
A.OH
A.STOP overheat pow. mod
89 Warning: Over temperature of power module
A.EF
ABN. STOP external fault
90 Warning: external error
A.ndOH
no A. drive overheat
91 Warning: no more over temperature of motor PTC. Motor PTC is
low resistance again.
A.nOHI
no A. STOP overheat int.
92 Warning: no more over temperature in the interior
A.bus
ABN.STOP bus
93 Warning: Watchdog for communication between operator/control
card has responded.
A.PRF
ABN.STOP prot.rot.for
94 Warning: locked direction of rotation clockwise
A.PRR
ABN.STOP prot.rot.rev.
95 Warning: locked direction of rotation counter-clockwise
A.dOH
ABN.STOP drive overheat
96 Warning: over temperature of motor PTC
A.OH2
ABN.STOP motor protect
97 Warning: electronic motor protective relay has tripped
A.nOL
no ABN.STOP overload
98 Warning: no more overload. OL counter has reached 0%
A.OL
ABN.STOP overload
99 Warning: Overload can only be reset at A.nOL, if OL counter has
again reached 0%
A.OL2
ABN.STOP overload 2
100 Warning: Overload can only be reset at A.nOL2 if cool down time
has elapsed
A.nOL2
no ABN.STOP overload 2
101 Warning: no more overload, the cool down time has elapsed
A.SET
ABN.STOP set
102 Warning: set selection: It has been attemped to select a locked
parameter set.
Display
Plaintext Combivis Value Meaning

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the M&R CHALLENGER II Series and is the answer not in the manual?

M&R CHALLENGER II Series Specifications

General IconGeneral
BrandM&R
ModelCHALLENGER II Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals