E 300 Operator Interface
M&R Printing Equipment, Inc. - Glen Ellyn, Illinois
55
been completed. You may enter a value up to a max-
imum of “999”. If you enter the value “0”, the “Ink
Dip” control feature will not operate. (See Figure 15
above)
Duration:
Duration is used to control the time interval for the
application of the adhesive. The maximum time
allowed is 0.70 seconds. The minimum is 0 seconds.
Larger (wider) pallets may required a longer time
duration that narrower pallets in order to apply adhe-
sive in a larger pattern.
To adjust the duration, press the “ARROW DOWN”
key one time so that the flashing cursor rests to the
left of the “Duration” menu selection. Now Press the
“ARROW RIGHT” key to move the flashing cursor
over to the value for “Duration”. Use the numerical
keys to enter your selection for the time duration,
then press the “ENTER” key. You selection is dis-
played for “Duration” in the L.C.D. window.
TESTS -
The next menu item is the “TEST” menu item. In the
“TESTS” menu item there are six sub-menu selec-
tions which are “Panel Test”, “Proximity’s Test”,
“Motion Card Test”, “Servo Drive Test”, “Servo
Motion Card History” and “Others” tests. The
“TESTS” menu provides an on-board self diagnostic
program which gives the system Operator a visual
indication of the operational integrity of all the prox-
imity switches, toggle switches and push button
switches used in the operation of the M&R
Challenger Series II system. To access the “Panel
Test” sub-menu, press the arrow keys to place the
flashing cursor on the small arrow to the left of the
words “Panel Test”, then press the “Enter” key. The
L.C.D. display window will now display a graphic
representation of the Main Control console.
As you select either “ON” or “OFF” the various
switches and push buttons used to control the sys-
tem, the particular switch or push button will
become highlighted on the graphic representation of
the control panel, indicating that it is working prop-
erly.
Figure 15
Ink Dip
Ink Dip Every: 0
Duration: 0.70 [s]
TIMERS
nozzle TESTS MPR Pg Dwn Pg Up