PREVENTIVE MAINTENANCE PROCEDURE
CHALLENGER Series II Bulletin No. PH2
Maintenance Point
(Pneumatic)
Frequency Interval
Procedure Information
Clean away old lubricant and apply a fresh coat of 1/3 white lithium grease (M&R Part No. 7018017) and 2/3 non-
detergent oil (M&R Part No. 7017000) to the print carriage guide shafts on each print station.
Weekly
Tools required:1 - M&R Part No. 7018017 White Lithium
Grease
1 - M&R Part No. 7017000 10 wt. non-deter
gent oil
1. Disconnect, lock out and tag the electrical and pneumatic
power from the equipment.
2. Disconnect the compressed air supply from the equip-
ment by closing the manual shut-off valve. The manual shut-
off valve is closed when the handle is positioned across the
air supply pipe/hose. (See illustration at right)
3. Bleed off any compressed air which may remain in the
system by opening the small pet-cock valve (turn handle
counterclockwise to open valve) at the bottom of the mois-
ture trap assembly. Allow any compressed air to completely
evacuate the system before closing (turn handle clockwise to
close) the pet-cock valve.
081200MS
83
The frequency of the following preventive maintenance procedure is
based on a 8 hour daily production shift or 40 hour work week.