Ü
50H-PERIODIC MAINTENANCE - EVERY 50 HOURS OF SERVICE OR 3 MONTHS
ALSO PERFORM THE DAILY AND WEEKLY MAINTENANCE.
CHECK Tightening of electrical connections
- Remove the right and left battery covers
1
.
- Remove the turntable cover
2
.
- Remove the rear chassis cover.
- Remove the electrical cover
3
.
- Open the left-hand turntable cover.
- Check that all the electrical connections are properly tightened:
• Batteries.
• Battery cut-off
4
.
• Hydraulic pump motor.
• Voltage controller
5
.
• Power relays module
6
.
• Wheel motors
7
.
- Put the electrical cover
3
back in place.
- Refit the rear chassis cover.
- Put the turntable cover
2
back in place.
- Put the battery covers
1
back in place.
GREASE Teeth on crown gear
NOTE: The left turntable cover is open.
- Lubricate the teeth of the crown gear
1
, eLUBRICANTS.
- Switch the platform on.
- Turn the turntable a full turn to spread the lubricant.
- Put the turntable in neutral position.
- Turn the platform off.
- Close the left-hand turntable cover.
CHECK Emergency controls
t
IMPORTANT
t
Never use the platform in the event of an emergency control failure.
- Check that the emergency controls are working, e2-DESCRIPTION: RESCUE PROCEDURE.