BLEEDING THE INJECTORS
- Loosen high pressure connectors 5 (Fig. H1/5) of two of the injectors.
- Activate the starter until the diesel fuel flows out free of air at connections 5
(Fig. H1/5).
- Tighten the connection while the diesel fuel is flowing out (Tightening torque
22 N.m).
The engine is then ready to be started up.
Turn the IC engine over slowly for 5 minutes immediately after bleeding the
fuel feed circuit, in order to ensure that the injection pump has been bled
thoroughly.
NOTE : If the engine functions correctly for a short time then stops or
functions irregularly, check for possible leaks in the low pressure
circuit. If in doubt, contact your dealer.