B9 – CAB VENTILATION FILTERS
CLEAN
EXTERNAL CAB VENTILATION FILTER
- Take out the cab ventilation filter 1.
- Clean the filter with a compressed air jet.
- Check its condition and change if necessary
(see: 3 - MAINTENANCE: FILTERS CARTRIDGES
AND BELTS).
- Reinstall the filter.
- Refit the protective casing 2.
INTERNAL CAB VENTILATION FILTER
- Remove the protective grid 3.
- Lift out cab ventilation filter 4.
- Clean the filter with a compressed air jet.
- Check its condition and change if necessary
(see: 3 - MAINTENANCE: FILTERS CARTRIDGES
AND BELTS).
- Reinstall the filter.
- Refit the protective grid 3.
B10 – CONDENSER CORE (AIR-CONDITIONING OPTION)
CHECK - CLEAN
IMPORTANT
In a polluting atmosphere, clean the radiator core every day.
Do not use a water jet or high-pressure steam as this could damage the condenser fins.
- Visually check whether the condenser is clean and clean it if necessary.
- Clean the condenser using a compressed air jet aimed in the same direction as
the air flow.
- Clean with the fans running for best results.
1
2
3
4
647563 (22/08/2017)
MT 1435/1440/1840 EASY 75D ST3B S1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitou MT 1435 EASY 75D ST3B S1 and is the answer not in the manual?

Manitou MT 1435 EASY 75D ST3B S1 Specifications

General IconGeneral
BrandManitou
ModelMT 1435 EASY 75D ST3B S1
CategoryFront End Loaders
LanguageEnglish

Related product manuals