14000 SERVICE MANUAL ELECTRIC SYSTEM
3
Crane Status
Displays crane errors. The number displayed in top bank
corresponds to the following:
• Number 0 = Crane status normal
• Number 1 = Node-2 is not communicating.
• Number 2 = Node-3 is not communicating.
• Number 4 = Node-4 is not communicating.
• Number 8 = Node 5 is not communicating.
• Number 128 = Engine node is not communicating.
NOTE: The bottom bank is not used at this time.
Status History
The top bank displays errors since power was last cycled.
NOTE: The bottom bank is not used at this time.
Boom Node Status
Displays boom top and luffing jib communication. The box
indicates what nodes may be available on the bus:
• Number 0 = Communication error
• Number 1 = Boom top node
• Number 2 = Luffing jib node
The status of the boom RIN shorting plug is shown at CAN
113-4-
• Number 32 = Plug not installed
• Number 33 = Plug installed
The status of the RIN system between the boom top RIN and
the luffing jib RIN is shown at CAN 84-8-
• Number 0 = signal low (open circuit: for example,
shorting plug not connected to boom top RIN).
• Number 64 = signal high (no communication).
• Number 128 = signal okay (RIN is communicating
properly).

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals