Reference Only
Manitowoc Published 09-10-14, Control # 065-24 3-41
14000 SERVICE MANUAL ELECTRIC SYSTEM
3
Crane Status
Displays crane errors. The number displayed in top bank
corresponds to the following:
Number 0 = Crane status normal
Number 1 = Node-2 is not communicating.
Number 2 = Node-3 is not communicating.
Number 4 = Node-4 is not communicating.
Number 8 = Node 5 is not communicating.
Number 128 = Engine node is not communicating.
NOTE: The bottom bank is not used at this time.
Status History
The top bank displays errors since power was last cycled.
NOTE: The bottom bank is not used at this time.
Boom Node Status
Displays boom top and luffing jib communication. The box
indicates what nodes may be available on the bus:
Number 0 = Communication error
Number 1 = Boom top node
Number 2 = Luffing jib node
The status of the boom RIN shorting plug is shown at CAN
113-4-
Number 32 = Plug not installed
Number 33 = Plug installed
The status of the RIN system between the boom top RIN and
the luffing jib RIN is shown at CAN 84-8-
Number 0 = signal low (open circuit: for example,
shorting plug not connected to boom top RIN).
Number 64 = signal high (no communication).
Number 128 = signal okay (RIN is communicating
properly).