3 Replacing appliance parts to rectify problems
Repair Manual C4 105
3.8.1 Removing and fitting the drain probe
Component
Name Part number
Drain probe (5B3) #######
Tools required
8mm/17mm open-ended wrench
Requirements
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures taken to
ensure the power cannot be switched on again.
The left-hand side panel has been removed.
The lower front panel has been removed.
The waste water has been cooled using the recoil hand shower.
The drain box has been emptied via the drainage pipe or using the Service menu.
Removing the drain probe
1. Undo the screw using an 8mm open-ended wrench and open the
floor hatch.
2.
Hinge down the cover.
3. Use a 17mm open-ended wrench to unscrew and remove the
drain probe.