3 Replacing appliance parts to rectify problems
Repair Manual C4 107
3.8.2 Removing and fitting the bypass sensor
Component
Name Part number
Bypass sensor (5B5) #######
Tools required
8mm open-ended wrench
17mm open-ended wrench
Requirements
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures taken to
ensure the power cannot be switched on again.
The left-hand side panel has been removed.
The lower front panel has been removed.
The waste water has been cooled using the recoil hand shower.
Removing the bypass sensor
1.
Undo the screw using an 8mm open-ended wrench.
2.
Hinge down the cover.
3. Use a 17mm open-ended wrench to unscrew and remove the
bypass sensor.

Table of Contents