3 Replacing appliance parts to rectify problems
Repair Manual C4 159
3.16.4 Removing and fitting the boiler burner fan
Component
XXXX Boiler burner fan
Tools required
8mm socket wrench
Requirements
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures taken to
ensure the power cannot be switched on again.
The gas supply has been shut off.
The left-hand side panel has been removed.
Removing the boiler burner fan
1. Remove the automatic firing devices and take off all the con-
nectors.
2.
Use an 8mm socket wrench to undo the two screws on the bracket
holding the burner fan in place.
3.
Remove the bracket from the burner fan.
4.
Remove the second bracket from the burner fan.
Take off the gas valve at the same time.