3 Replacing appliance parts to rectify problems
Repair Manual C4 164
Item Name Quantity
9
Ventilation-port inlet pipe 6.10 1
10
Screw 4.8x25 A2 DIN 7982 5
11
Bolt M8x40 DIN 933 4
12
Exhaust vent pipe 1
13
Rubber gasket 1
14
Mounting bracket for exhaust vent pipe 1
15
Support frame (for rollers) 1
16
Rollers 4
17
Bolt M8x70 DIN 931 4
18
Screw 4.8x80 DIN 7976 1
Tools required
Size 6 Allen key
7mm socket wrench
8mm socket wrench
13mm open-ended wrench
Phillips screwdriver
File
Requirements
Check that the following requirements have been met:
The appliances have been disconnected from the power supply.
The appliances have been disconnected from the water supply and wastewater handling system.
The appliances are cool.
The cooking chamber in each appliance is empty (rack, suction panel, sheet pans, ...)
In both appliances, all tanks (collector box, boiler and drain box) and all hoses have been pumped
empty.
The cleaning-fluid connections have been removed.
Any peripheral accessories (hood or heat shield) have been removed.
The stacking-kit components have been removed from the packaging and the contents checked to
ensure that all parts are present.
There are up to four people available at certain times for moving and lifting the appliance.
Fitting the stacking kit
1.
Use a spirit level to make sure the support frame for the stacking
kit is horizontal.
1.a
Stacking kit with 100 mm foot height
Place the base frame in the intended installation location and
adjust the feet until the frame is level horizontally.
1.b
Stacking kit with 150 mm foot height
Place the support frame for the stacking kit in the intended
installation location and adjust the feet until the frame is level
horizontally.