9.6 Summary of gas data
Convotherm 4 GB/GS
The table below lists the possible gas data (as per CE) at 15°C and 1013 mbar dry:
Gas type and symbol Natural gas 2H
(E)
Natural gas 2L
(LL)
Liquefied gas
3B/P
Propane 3P
Supply flow pressure [mbar] 17 - 25 18 - 30 20 - 57.5 25 - 57.5
Wobbe index
Lower W
u
[MJ/m
3
]
45.7 37.4 80.6 74.8
Upper W
o
[MJ/m
3
]
50.7 41.5 87.3 81.2
Thermal value
H
i
[MJ/m
3
]
34 29.3 116.1 88
H
i
[MJ/kg] - - 45.7 46.3
Calorific value
H
s
[MJ/m
3
]
37.8 32.5 125.8 95.7
H
s
[MJ/kg] - - 49.5 50.4