3.
Fit a separate shut-off device for each appliance.
4
.
If a backflow preventer or check valve are required (see
connection diagram), fit the relevant device in the water
supply line.
5
.
Connect the appliance as shown in the connection plan.
6
.
Flush through the sediment filter by operating the recoil
hand shower.
7
.
Once the water supply has been installed, close the shut-
off device.
8
.
Inform the user about the service intervals for the filters,
and the water treatment equipment if applicable.