MODEL YB8 MAINTENANCE
April 1999/Manning Environmental Inc.
Page C-9
The refrigerator that comes with the YB8 is an industrial grade unit. It has many features and options that
are not found on consumer models. These features make it more resistant to weather, allow it to maintain
EPA recommended temperatures, and ensure long life in the harshest environments. As durable as the
refrigerator is there are things that can be done to promote longer life. These items are covered here, but are
also covered in the manual that comes with the refrigerator. If you should encounter problems that cannot be
addressed with this manual or the manual included with the refrigerator, please contact Manning for
assistance.
Condenser
The condenser tubing under the cabinet for forced air units does not require frequent
cleaning; however, satisfactory cooling depends on adequate ventilation over the
condenser. Be sure that nothing obstructs the air flow openings in the lower front of the
cabinet. At least once or twice a year brush or vacuum lint and dirt from the condenser
for efficient performance by unscrewing the grill on the bottom front o f t he cabinet
Cabinet
The stainless steel o r painted cabinet can be washed with mild soap and water and
throughly rinsed with clear water. Never use abrasive scouring powders.
Interior and Door Gasket
Wash interior compartment with mild soap and water. M ix 2 tablespoons of baking soda
with one quart of warm water. Do not use abrasive powders, solvent, polish cleaner or
undiluted detergent.
Energy Saving Tips
A. Reduce door openings as much as possible
B. Close the door as soon as possible after opening
C. Keep the coils on the bottom of the refrigerator clean
D. Adjust the temperature control to a warmer temperature when maintaining 4 C is
0
not necessary
E. Dont put hot material into the refrigerator
F. Keep the refrigerator away from heat generating equipment
Troubleshooting
Problem Possible Cause/Solution
Odor in Cabinet Interior needs cleaning
Noisy Operation Cabinet not level
Cabinet Vibrates Cabinet not level
Appliance will not run Temperature control t urned t o OFF
Line cord not plugged in
No power at electrical outlet
Blown fuse

Table of Contents