4. PROTECTION MODE
Explanation of microprocessor (QU01) [PROT-1 (pin6) and
PROT-2 (pin7)].
[A] The PROT-1 (pin6) is the port to detect the following
abnormalities of the Power AMP
Detection of an abnormality in the DC offset voltage from 1.
the Speaker Output terminal.
If the voltage from the Speaker Output terminal exceeds
approximately 1.2V (DC), Q955 or Q956 will turn on and
the signal from the PROT-1 terminal will change to L from
H.
Detection of an abnormal current from the power 2.
transistors (Q713 ~ Q716).
If an electric current of over 7A flows in Q713 or Q715,
Q951, Q953 and Q957 turn on, and the signal from the
PORT-1 terminal will change to L from H.
If an electric current of over 7A flows in Q714 or Q716,
Q952, Q954 and Q957 turn on, and the signal from the
PORT-1 terminal will change to L from H.
Detection of an abnormal temperature of the Heat Sink.3.
If the temperature of the Heat Sink exceeds
approximately +110 degrees C, the posistor (R969) will
turn on Q958 and the signal from the PROT-1 terminal
will change to L from H.
If any of the above three abnormalities is detected, the
signal from the PROT-1 terminal will change to L from H,
and the protection circuit will be activated, the signal from
the SPK_OUT (pin10) changing to H from L and the speaker
relays L751, L752 and L753 immediately turned off.
What this protection operation results in after this depends
on how long the signal from the PROT-1 has to remain L.
• If the PROT-1 (pin6) recovers to "H" within as short a
period of time as one second or less.
The MUTE indicator starts flickering, thereby indicates
that the protection circuit has come into operation and
automatically turns down the volume. The protection
circuit is deactivated after approximately 15 seconds,
so that readjusting the volume will allow normal use
of the unit again. This protection operation is intended
for the situation wherein the user has misused the unit
temporarily and automatically resets the unit while the
amp circuit is functioning properly.
• If the PROT-1 (pin6) remains L for more than one second.
The amp will be powered off by the P_ON (pin15)
changing to H from L and Power relay L852 turned off
Then, the STANDBY indicator flickers, thereby indicating
that an error has occurred. This protection operation is
intended for a failure in the amp circuit and immediately
turns the power off to avoid the risk of any damage.
Depending on how the user is handling the unit, this
operation may be performed no matter if the amp is
functioning properly.
4. PROTECTION動作について
マイコン(QU01)のPROT-1 (pin6)とPROT-2 (pin7)の説明。
[A] PROT-1 (pin6)は、パワーアンプの下記の異常動作を検出
するポートです
スピーカー出力端子の
DCオフセット電圧の異常電圧を検1.
出。
スピーカー出力端子が約1.2V (DC) を超えるとQ955もしく
は
Q956がONして、PROT-1端子が "H→L" になる。
パワートランジスタ
(Q713〜Q716)の異常電流を検出。2.
Q713
もしくはQ715に約7Aを超える電流が流れるとQ951,
Q953, Q957
がONして、PROT-1端子が "H→L" になる。
Q714もしくはQ716に約7Aを超える電流が流れると
Q952,Q954,Q957がONして、PROT-1端子が "H→L" にな
る。
ヒートシンクの異常温度を検出。
3.
ヒートシンクの温度が約110℃を超えると、ポジスター
(R969)によってQ958がONして、PROT-1端子が "H→L" に
なる。
1.〜 3.のいずれかの異常検出でPROT-1端子が "H→L" になる
と保護回路が動作して、
SPK_OUT (pin10) を "L→H" にし
て、即座にスピーカーリレー
L751, L752, L753をOFFにしま
す。
この
PROTECTION動作はPROT-1端子が "L" になっている時
間によって、その後の動作が異なります。
• PROT-1 (pin6)が1秒以内の短時間の間に "H" に復帰した場
合。
MUTEインジケーターが点滅しPROTECTION動作になっ
たことを知らせ、自動的にボリュームを下げます。
約15秒後に保護回路が解除しますのでボリュームを再調整
すればそのまま使用することができます。
これは、ユーザーが一時的に使用法を誤った場合を想定し
た
PROTECTION動作で、アンプ回路は故障していない場
合に自動復帰する動作です。
• PROT-1 (pin6)が1秒以上 "L" になっている場合。
P_ON (pin15) を "L→H" にして電源リレー L852 をOFF
し、アンプの電源をシャットダウンします。
このときSTANDBYインジケーターが点滅し、異常が起き
たことを表示します。
これは、アンプ回路の故障を想定したPROTECTION動作
で、危険回避のため即座に電源を切る動作です。
ユーザーの使用状況によっては、アンプが故障していなく
てもこの状態になる可能性もあります。
アンプが故障しているかどうかを確認するには、一旦電源
SW
を切り1分ほど待ってから電源SWを再投入します。
この操作で
PROTECTION動作が解除します。
電源
SWを再投入してもPROT-1 (pin6)が "L" の異常状態の場合
は、約
3秒後に再びシャットダウンしてSTANDBYインジケー
ターが点滅します。
電源を再投入しても
PROTECTION動作が解除されない場合
は、アンプ回路が故障していると考えられます。