ENGLISH
31
BASIC
CONNECTIONS
BASIC OPERATION
ADVANCED
CONNECTIONS
SETUP
ADVANCED
OPERATION
TROUBLESHOOTING
OTHERS
NAMES AND
FUNCTION
SETUP
Select CALCULATE” with the 3/4 cursor
buttons and press the ENTER button to calculate
measurement results. During calculations, the
following OSD appears on the display.
AUTO SETUP
______________
NOW CALCULATING !
Audyssey MultEQ
Note:
• Fewer than 6 positions may be measured, but it
is recommended to measure in all 6 positions for
best results. Measuring in just one position is
not recommended as it does not provide enough
acoustical information to the MultEQ algorithm.
• The time needed to complete calculations depends
on the number of connected speakers and measured
listening positions. The more speakers and listening
positions, the more time is needed.
9.
Checking Measurement Results
When calculations for the measurement results
end, a screen appears for confirming the
calculation results.
CHECK RESULT
SPEAKER CONFIG
SPEAKER SIZE
DISTANCE
CHANNEL LEVEL
CROSSOVER FREQ
STORE
Audyssey MultEQ
EXIT
Select items to check with the 3/4 cursor
buttons and press the ENTER button to enter
them.
Note:
To check equalizer (MultEQ) parameters, see page
41.
[Example]
Confi rmation screen for speaker detection
SPEAKER CONFIG
CHECK !! SPEAKER
FRONT L : YES
CENTER : NO
FRONT R : YES
SURR.R : YES
SURR.B R : NO
SURR.B L : NO
SURR.L : YES
SUB W : YES
RETURN NEXT
10.
Storing Measurement Results in Memory
Once finished confirming the measurement
results, select RETURN” with the 3/4 cursor
buttons and press the ENTER button to display
the CHECK RESULT screen.
CHECK RESULT
SPEAKER CONFIG
SPEAKER SIZE
DISTANCE
CHANNEL LEVEL
CROSSOVER FREQ
STORE
Audyssey MultEQ
EXIT
Place the cursor on “STORE” and press
the ENTER button to store all parameters
including the equalizer parameters in memory.
If not wanting to store the calculation results in
memory, place the cursor on “EXIT and press
the ENTER button.
Note:
Pressing “EXIT” prior to pressing “STORE” erases all
measurement results and calculation results, therefore
operate the remote controller with care.
When storing operations end, the following OSD
appears on the display.
2.SPKR SETUP
AUTO SETUP
MANUAL SETUP
RETURN EXIT
Notes:
Do not turn the power to the unit off while storing
parameters in memory. This may erase all data in the
unit’s memory and may damage the unit.
[Example] Confi rmation screen for speaker size.
SPEAKER SIZE
FRONT L : AUTO
CENTER : AUTO
FRONT R : AUTO
SURR.R : AUTO
SURR.B R : AUTO
SURR.B L : AUTO
SURR.L : AUTO
RETURN NEXT
[Example] Confi rmation screen for the distance from
speakers to the listening position
DISTANCE
UNIT : ft
FRONT L : 30.0ft
CENTER : 19.3ft
FRONT R : 29.6ft
SURR.R : 21.5ft
SURR.B R : 12.3ft
SURR.B L : 11.6ft
SURR.L : 16.3ft
SUB W : 12.5ft
RETURN NEXT
* The units can be changed by moving the cursor to
[ft] of UNIT and pressing 1 / 2 the cursor buttons.
Each time a 1 / 2 cursor button is pressed, the units
alternate between [ft] (feet) and [m] (meters).
Note:
This system cannot measure a distance of 30.0 ft
(9.15 m) or higher. In this case, >30.0 ft (>9.15 m) is
displayed.
[Example] Confi rmation screen for channel level.
CHANNEL LEVEL
FRONT L : 0.0dB
CENTER : -6.5dB
FRONT R : -1.5dB
SURR.R : +1.0dB
SURR.B R : +9.5dB
SURR.B L : +12.0dB
SURR.L : -2.5dB
SUB W : -12.5dB
RETURN NEXT
[Example] Confirmation screen for crossover
frequency.
CROSSOVER FREQ
FRONT : AUTO
CENTER : AUTO
SURR : AUTO
SURR.B : AUTO
RETURN
* AUTO is displayed to indicate that the speaker size
and crossover frequency results were automatically
measured.
SR5003U1ENG23.indd31SR5003U1ENG23.indd31 08.7.44:48:38PM08.7.44:48:38PM