Control menu 33
UTIL
(Press
and hold
Enter for a
few
seconds
to use this
menu)
FEbA
ON
Enable pan/tilt position correction system
OFF
Disable pan/tilt feedback. Setting not saved.
EFFb
ON
Enable on the fly reset of color, gobo, and effect wheels
OFF
Disable on the fly reset of color, gobo, and effect wheels
Adj -
See Table 5
CAL/P OF 1-255
Pan offset
CAL/T OF 1-255
Tilt offset
CAL/d OF 1-255
Dimmer offset
CAL/C OF 1-255
Cyan offset
CAL/M OF 1-255
Magenta offset
CAL/Y OF 1-255
Yellow offset
CAL/CTOF 1-255
CTC offset
CAL/COOF 1-255
Color wheel offset
CAL/G1OF 1-255
Gobo wheel 1 offset
CAL/G2OF 1-255
Gobo wheel 2 offset
CAL/EFOF 1-255
Effect wheel offset
CAL/IROF 1-255
Iris offset
CAL/FOOF 1-255
Focus offset
CAL/ZOOF 1-255
Zoom offset
dFOF SURE
Return all offsets to the default settings
PCbT LEd
PCB test for service use only.
FANS REG
Regulate the effect cooling fans for quieter performance. Enabling
this option increases the operating temperature and thus increases
wear on the components.
FULL
Operate cooling fans at full speed. This is the default from software
version 1.4.
UPLd SURE
Manually set fixture to software update mode
SMSG
Replace lamp
Displayed when lamp hours exceed average life (750 hours)
Fixture overheating
Displayed if head temperature exceeds 120° C (248° F)
Menu Item Options Notes (Default settings in bold print)
Table 4: Control menu