Routine maintenance 21
Software installation
Software updates are installed in the MAC 2000 Wash using a Martin MP-2 Uploader or a LightJockey 4064 DMX
interface card. The procedure is found in the MP-2 user manual and the Martin Software Uploader online help file.
REQUIREMENTS
The following are required in order to install software.
• The MAC 2000 Wash update file, available for download from the User Support Area of the Martin web site
(http://www.martin.dk).
• The Martin Software Uploader program, version 4.0 or later, available for download from the User Support Area of the
Martin web site.
• A Martin MP-2 Uploader connected to a Windows 95/98 PC, or a LightJockey Controller (DJ or Club) with 4064
DMX Interface card.
BOOT SECTOR JUMPER
If the normal upload procedure does not work, or if the software update notes call for a boot sector update, move the
boot sector jumper at PL103 to the BOOT position before uploading software.
To set the boot sector jumper
1 Disconnect the fixture from power.
2 Remove the top screws from the ends of the front side panel and tilt the
panel down to expose the main circuit board.
3 Using the diagram in “Circuit board connections” on page 33 or the label
inside the base, locate PL13. Move the jumper to the “BOOT” position.
4 Perform a boot mode upload. When the upload is complete, disconnect the
fixture from power and move the jumper back to the “NORM” position.
PL13
LOCK setting (default)
PL13
Boot setting
Figure 11: Setting the boot sector
jumper