MAC 2000 Profile
user manual

Questions and Answers

  • S
    Sandra BrownJul 31, 2025
    What to do if my Martin MAC 2000 Profile has no light and displays 'LERR'?
    • C
      Cody RomeroJul 31, 2025
      If your Martin Lighting Equipment displays a 'LERR' error message and there is no light, several issues could be the cause: * The ballast and transformer settings might not match your local AC voltage and frequency. If that's the case, disconnect the fixture and check these settings, correcting them if necessary. * The lamp might be blown. Disconnect the fixture and replace the lamp. * The lamp might not be installed. Disconnect the fixture and install the lamp. * The lamp access safety switch might be open. Make sure the lamp access plate is fully seated and locked. * The lamp might be too hot to strike. Send a lamp off command, allow it to cool for 5-10 minutes, and then try again.
  • D
    Donald GarciaAug 10, 2025
    What causes my Martin MAC 2000 Profile lamp to cut out intermittently?
    • H
      Holly BarrAug 10, 2025
      If the lamp in your Martin Lighting Equipment cuts out intermittently, it could be due to the following reasons: * The fixture might be too hot. Allow it to cool, clean the air filters, and reduce the ambient room temperature. * The ballast and transformer settings might not match your local AC voltage and frequency. Disconnect the fixture and check these settings, correcting them if necessary.
  • R
    Rebecca WheelerAug 15, 2025
    How to troubleshoot a completely dead Martin MAC 2000 Profile fixture?
    • R
      rosarioashleyAug 15, 2025
      If one or more of your Martin Lighting Equipment fixtures is completely dead, here's what you can check: * Ensure the fixture is receiving power by verifying that the power is switched on and the cables are properly plugged in. * Check the primary fuse (located near the mains inlet). If it's blown, disconnect the fixture and replace the fuse. * Inspect the secondary fuses (located on the PCB inside the base). If any are blown, disconnect the fixture and replace them.
  • A
    Alexandra KelleyAug 20, 2025
    Why does the magnetically indexed effect wander in my Martin Lighting Equipment?
    • M
      Melinda Wallace MDAug 20, 2025
      If the magnetically indexed effect in your Martin Lighting Equipment resets correctly but wanders after the fixture reaches operating temperature, it is possible that the effect wheel requires mechanical adjustment. Disable effects feedback.
  • B
    Brittany HornAug 25, 2025
    What to do if mechanical effect loses position on Martin Lighting Equipment?
    • C
      Christopher AtkinsonAug 26, 2025
      If a mechanical effect loses position in your Martin Lighting Equipment, it may be because the transformer setting does not match local voltage. Disconnect the fixture and check the transformer setting and correct it if necessary.
  • S
    Sherri KelleyNov 4, 2025
    How to fix Martin Lighting Equipment that resets but responds erratically?
    • J
      Janice MackNov 4, 2025
      If your Martin Lighting Equipment resets correctly but responds erratically or not at all to the controller, consider the following: * Inspect connections and cables for a bad data link. Correct any poor connections and repair or replace damaged cables. * Ensure the data link is terminated by inserting a termination plug in the output jack of the last fixture on the link. * Check the fixture address and protocol settings to ensure correct addressing. * Bypass one fixture at a time to check if one fixture is disturbing data transmission. Unplug the XLR in and out connectors and connect them directly together. Have the fixture serviced by a qualified technician. * If the XLR pin-out on fixtures does not match (pins 2 and 3 reversed), install a phase-reversing cable between the fix...

Summary

INTRODUCTION

Safety Information

Essential safety precautions for operating the fixture.

LAMP

Lamp Replacement Procedure

Important safety and procedure for replacing the lamp.

AC POWER

Fuse Specifications

Details on the types and ratings of fuses used in the fixture.

Power Supply Adjustment Guide

Information on adjusting power supply settings for different models.

AC Power Connection

Instructions for connecting the fixture to AC power.

DATA

Data Link Connection Procedure

Step-by-step guide to establishing DMX data connections.

RIGGING

Clamping Fixture to Truss

Detailed steps for securely mounting the fixture onto a truss.

CONTROL PANEL

Control Panel Navigation

How to navigate the control panel menus and options.

DMX Address and Protocol Setting

Setting the DMX address and choosing the protocol mode.

Service Messages Interpretation

Explains messages indicating service requirements.

Effect Calibration Procedure

Utilities for fine-tuning optical alignment and performance.

Calibrating Effects Step-by-Step

Step-by-step guide to calibrating various effects.

OPTICAL CONFIGURATION

Replacing Rotating Gobos

Procedure for replacing gobos in the rotating gobo wheels.

Replacing Color Filters or Gobos

Steps for replacing color filters and gobos in the color/gobo wheel.

Replacing Rotating Effects

Procedure for replacing effects in the effect wheel.

ROUTINE MAINTENANCE

General Cleaning Guidelines

General guidelines and warnings for cleaning the fixture.

Cleaning Optical Components

Detailed steps for cleaning lenses and optical parts.

Cleaning Fans and Air Vents

How to clean cooling fans and air vents.

DMX PROTOCOL

DMX Channel Mapping

Continuation of DMX channel mapping for functions.

CONTROL MENU

Control Menu Overview

Continued details on menu items and their functions.

ADJUSTMENT SUBMENU

Adjustment Menu Details

Detailed table for making mechanical adjustments to the fixture.

DISPLAY MESSAGES

Display Message Guide

Explains messages displayed by the fixture and required actions.

TROUBLESHOOTING

Troubleshooting Guide

Common problems, probable causes, and suggested remedies.