User Manual 23
The ballast and transformer
settings do not match local AC
voltage and frequency.
Disconnect fixture. Check ballast and
transformer settings and correct if necessary.
(MAC 600 E) Incorrect ballast type
selected.
Check S/N and set ballast type personality
accordingly.
Misaligned lamp.
Adjust lamp.