30 MAC Viper Performance User Guide
Service and display messages
The MAC Viper Performance gives service and maintenance information by displaying a large 3- or
4-character short code and a smaller full-text message in the fixture’s display. The short code is visible at a
distance, allowing easier reading with the fixture still in the rig, for example, while the full-text message gives
more detailed information.
Warning messages
Warning messages indicate that either:
• problems might appear in the future if no action is taken, or
• the user needs to pay special attention to a function or procedure when working with the fixture.
The MAC Viper Performance communicates warnings as follows:
• Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
• If more than one warning is detected, all warnings are displayed in sequence.
• If the display is inactive, the fixture’s status LED (see Figure 5 on page 10) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
The possible warning messages are listed in Table 3 below
:
Short code
Long message and explanation
BANK
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BATW
BAL TEMP HIGH
Ballast PCB sensor detects that normal operating temperature is exceeded.**
CMTW
CMY TEMP HIGH
CMY PCB sensor detects that normal operating temperature is exceeded.**
DINA
DIMMER ADJUST
No dimmer adjustment data in EEPROM. Dimmer may be incorrectly adjusted*.
EFTW
EFF TEMP HIGH
Effects PCB sensor detects that normal operating temperature is exceeded.**
FRNA
FRAMING ADJUST
No framing adjustment data in EEPROM. Framing effect may be incorrectly adjusted*.
FTNA
FROST ADJUST
No frost adjustment data in EEPROM. Frost effect may be incorrectly adjusted*.
G1xM
GOBO 1-x MISSING
Gobo x not detected at last reset. If no gobos are detected, an RxER message is also displayed.
HOT
LAMP HOT
Lamp is too hot to restrike. Pan and tilt are disabled for 8 minutes to reduce the risk of falling
fragments if the lamp has exploded. Fixture will attempt to restrike at one-minute intervals. If
lamp still refuses to strike after eight attempts, an LAER (Lamp Error) message is displayed.
INLK
INVALID LICENSE KEY
Invalid license key entered. Warning is displayed and it is impossible to enter a license key for
10 seconds.
LTIM
LAMP LIFETIME
Lamp lifetime counter has timed out.
PTTW
PT TEMP HIGH
Pan/tilt PCB sensor detects that normal operating temperature is exceeded.**
PUTW
PSU TEMP HIGH
Power supply unit PCB sensor detects that normal operating temperature is exceeded.**
Table 3: Warning messages