34 MAC Viper Performance User Guide
SLER
SAFETY LOOP
Lamp safety loop circuit activated. Lamp temperature circuit breaker has cut lamp power. Circuit
breaker resets automatically after lamp temperature has returned to normal operating range.
SSTO
SYSSTATE TIMEOUT
Some part of the system did not startup as expected. This error message is usually followed by
other more descriptive messages. Service intervention required. Fixture control possibly
disabled, depending on nature of error.
TIER
TILT ERROR
Tilt position electrical indexing circuit timeout.
TSER
TILT SENSOR ERR
Fixture unable to retrieve reliable data from tilt position sensor.
UECM
UPL ERR CMY
Could not upload new firmware to the color mixing system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEEF
UPL ERR EFFECT
Could not upload new firmware to the projection system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEPT
UPL ERR PAN/TILT
Could not upload new firmware to the pan/tilt system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEUI
UPL ERR UI
Could not upload new firmware to the user interface system.
UEZF
UPL ERR Z/F
Could not upload new firmware to the zoom/focus system.
UITC
UI TEMP CUT OFF
User interface PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set
to max. Error cleared when fixture is reset.
UPLD
DMX UPLOAD ERROR
An error occurred during upload via DMX. Check cabling and connections, and then restart.
YEER
YELLOW ERROR
Yellow position electrical indexing system timeout.
ZFTC
ZF TEMP CUT OFF
Zoom/focus PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to
max. Error cleared when fixture is reset.
ZOER
ZOOM ERROR
Zoom position electrical indexing system timeout.
Short code
Long message and explanation
Table 4: Error messages