46 Martin VDO Atomic Dot user guide
Beam/Strobe LED VDO Atomic Dot WRM
Max. total lumen output.........................................................................................3000 lumens
Beam angle .......................................................................................... 11 degrees (half peak)
Field angle....................................................................................22 degrees (one-tenth peak)
Color temperature ...........................................................................................................2700K
Resolution ........................................................................................................................ 16-bit
Minimum LED lifetime ............................................ 50 000 hours (to >70% luminous output )*
Aura backlight LEDs
Color temperature ........................................................................................................ Variable
Resolution ...........................................................................................16-bit per color per pixel
Minimum LED lifetime ............................................ 50 000 hours (to >70% luminous output )*
*Figure obtained under manufacturer's test conditions:
Construction
Color..................................................................................................................................Black
Housing material ....................................................................................................... Aluminum
Protection rating ................................................................................................................. IP65
RoHS......................................................................................................................... Compliant
REACH...................................................................................................................... Compliant
Installation
Mounting Options ........ hanging from bracket, hanging from clamp attached directly to fixture
......................................................... or hanging from other fixture using interlock mechanism
Clamp attachment to hanging bracket ............................................................................... M12
Clamp attachment directly to fixture..................................................................................... M8
Maximum vertical column height...............................................................................16 fixtures
Orientation........................................................................................................................... Any
Minimum distance to combustible materials .................................................................... 0.1 m
Minimum distance to illuminated surfaces ....................................................................... 0.2 m
Location..................................................................................indoor or temporary outdoor use
Connections
VDO Atomic Dot fixture
AC power, DMX and Network input .....................Cable tail with PDE hybrid connector (IP65)
AC power, DMX and Network thru..................... Chassis mount PDE hybrid connector (IP65)
Hot plugging ............................................................................................................ Compatible
PDE Junction Box
AC Power input ......................................................................Neutrik powerCON TRUE1 TOP
......................................................(IP65 when mated with matching Neutrik cable connector)
DMX input.....................................................................................Neutrik XLR 5-pin Male TOP
......................................................(IP65 when mated with matching Neutrik cable connector,
..................................................................... compatible with standard 5-pin XLR connectors)
Ethernet input....................................................................................... Neutrik etherCON TOP
..................................................... (IP65 when mated with matching Neutrik cable connector,
.........................................................compatible with standard etherCON Cat 5E and Cat 6A,
.....................................................................NOT compatible with etherCON Cat 6 push-pull)
AC Power, DMX and Network output.................. chassis-mount PDE hybrid connector (IP65)
Hot plugging ............................................................................................................ Compatible
Electrical
AC power.................................................................................... 100-240 V nominal, 50/60 Hz
Power Supply Unit........................................................... Auto-ranging electronic switch mode
Maximum power consumption .......................................................................................... 55 W
Typical half-cycle RMS inrush current ............................................................................ 1.12 A
Typical earth-leakage current.......................................................................................0.25 mA