Mass Combi Ultra 12/3000-150, 24/3500-100, 48/3500-50 – User and Installation Manual
25
6.2.3 List of event commands
This is the Mass Combi Ultra event commands list. Other MasterBus connected devices can be configured to initiate these
commands
Event command
Description
Inverter On/Off
Change the Mass Combi Ultra inverter state to On/Off
Charger On/Off
Change the Mass Combi Ultra charger state to On/ Off
Bulk
Changes to charge phase Bulk
Absorption
Changes to charge phase Absorption
Float
Changes to charge phase Float
Mains limit A
Fuse setting of the Mains input is set to 6 A (adjustable)
Mains limit B
Fuse setting of the Mains input is set to 10 A (adjustable)
Mains limit C
Fuse setting of the Mains input is set to 16 A (adjustable)
AC out 2 enabled
Switched Output-2 is enabled
Force Sec charge
Force charging of the second battery
Power off
Command to switch off the charger, inverter and open the input relais
Silent mode
Command to switch on/off the silent mode