Mass Combi Ultra 12/3000-150, 24/3500-100, 48/3500-50 – User and Installation Manual
8 TECHNICAL DATA
8.1 Specifications
230 V (±2 %) (adjustable 180 – 260 V)
50/60 Hz (±0.005%) configurable
Continuous power
@Tamb=25˚C, cos phi = 1
Continuous power@Tamb=40˚C, cos phi = 1
True sine wave, Thd < 1 % under standard conditions
Dynamic input window battery
Programmable, current dependent switch-off levels, vary with set battery type
(Gel / AGM settings below)
Switch off voltage low battery@ load ≤ 2%
Switch off voltage low battery@ load 2-100%
Switch on voltage low battery
Switch off voltage high battery
Switch on voltage high battery
Max. ripple on DC @ full load
Nominal DC current at full load
Inverter off mode (remote)
Battery charger specifications
AGM / Gel / MLi / Flooded / Flooded traction / Spiral / NiCad
Battery temperature sense
Input present, sensor included
Only through MasterShunt, else automatic compensation
Max. charge current @Tamb=40˚C
150 A @ 14.25 V
adjustable
100 A @ 28.5 V
adjustable
Follows main charge (if sec. V < main V) / Fixed (power supply)
Secondary charger output current
Transfer system specifications
AC input 1 (“GEN”) (switched)
AC input 2 (“MAINS”) (switched)
AC Output 2 (“OUT-2”) (switched)
Transfer voltage range (adjustable)
Transfer frequency range (adjust.)
Auto-synchronize with AC input 1 / 2