516532 B PUBLICATION DATE 1 JUN 2007.DOC PROGRAMMING MANUAL 17
Menu Item Default Info Limits
Language English Language selection: English, Spanish, French List
Compart. Flush Pre-Wash Yes Makes sure that the first soap dispenser
Compartment is always Flushed at the end of the
Wash Sequence.
No / Yes
Hot water Heater Temp. 140°F It is recommended to set temperature of Hot water
supply to obtain a more accurate water
temperature control during the fill process.
122° - 176°F
Max Water Fill Time 7 Min Diagnostic D7 is generated if the machine is not
filled within it’s maximum allowed water fill time.
For a value of 99, no Diagnostic is generated at all.
5 – 99 Minutes
Overfill Detection 10 units Diagnostic D15 is generated when machine fills
water 10 units above programmed water level.
10 – 25 units
Exit Return to Main Menu