516532 B PUBLICATION DATE 1 JUN 2007.DOC PROGRAMMING MANUAL 19
• All the Initialization and Configuration Menu settings will be
cleared and the default Factory settings will be re-installed.
• This function should only be used at the initialization of a new
Graphic Control Wash Computer.
Menu Item Default Info Limits
Machine Type MFR18 Machines : MFR 18, 25, 30, 40, 50, 60, 80
Machines : MFS 18, 25, 35, 50
List
Reset Factory Settings?
Are You Sure ?
No Complete reset of wash computer.
A new wash computer must be Factory Reset.
No / Yes
Brightness Display 12 Sets the Visualization angle of the Display. 0 – 25
Load Inverter Param. ?
Are You Sure ?
No Loads the Inverter Parameters into the inverter.
THIS IS DONE WHEN A NEW INVERTER IS
INSTALLED.
No / Yes
Temperature Fahrenh Select temperature in °F or °C. List
Erase all Wash Prog ?
Are You Sure ?
No Complete reset of the wash programs.
Existing values are erased completely.
No / Yes
Load Stand. Programs ?
Language (English)
Load Program 1 – 6 ?
No Language selection of the titles of the Wash
Programs.
Wash Programs 1-6, as shown in Manual, are
loaded.
No / Yes
Exit Return to Main Menu
Reset Factory Settings ?
Service Faults