5 - 5
Maintenance
Use wrench to remove existing gauge.
Add or remove hydraulic fluid until the level is approximately 1/2”
from the top of the port.
Reinstall gauge with Teflon tape applied to threads. Check to see if
the needle indicates pressure as the gauge is being screwed on. If
so, remove the gauge and use a clean rag to remove some hydraulic
fluid. Repeat until no pressure is indicated while screwing gauge on.
NOTICE: When applying Teflon tape, make sure that the tape does
not overhang the end of the pipe threads. The threads will cut off the
tape and the small pieces will plug the orifice of the gauge.
TX01596-3-17-99
PH01527-3-19-99
PH01526-3-19-99
PH01523-3-19-99 PH01524-3-19-99