Water Heater Trouble Shooting
Gas Operation
When switching on, the heater
does not operate.
voltage.
(operation voltage min. 10.5 V).
Check the Truma UltraRapid fuse
(refer to maintenance “Fuses”).
When switching on, the heater
does not operate, and the red lamp
lights up after approx. 30 secs.
– Air in the gas
supply.
– No gas supply.
– Incorrect gas
pressure.
or clear any obstruction.
Check gas valves and gas cylinder.
To unlock (and purge air),
switch off the appliance,
wait 5 minutes, and switch
Heater operates for a prolonged
time and then the red lamp lights
up.
temperature
thermostat has
responded.
Check water level, refill if
required (close drain
valve).
To unlock, switch off the
appliance, wait 5 minutes,
Water Supply
safety valve.
– Water pressure to high.
– Lime or dirt under the
P&T safety valve seat.
Check water pressure (max.
400 kPa), use a pressure
reducer when connected
to central water supply.
Allow the appliance to cool
and then slowly raise the
test lever (Fig. 2a – 4a) to
flush the water system and
attempt to force dirt or
foreign matter out of the
P&T safety valve seat.
Replace P&T safety valve.
This must be performed
only by a certified service
water tap, hot water comes
out.
through the cold water
supply.
-Fit a non-return valve in
the cold water supply
(refer to installation
instructions “Water
connection”).
-Non return valve faulty