www.marketdirect.com.au
Ph: 1300 494 494 I ©Copyright Page | 64
Water
Pump not working (no noise)
No power from control panel Check circuit breaker
Flat Battery Charge battery
Faulty pressure switch
Replace pump, Contact
dealer for replacement
Bad electrical connection
Check connections with
multimeter or test light
Pump working but no water
flow
Airlock in water lines
Turn on tap and hold finger
over nozzle for 5 seconds and
release. Repeat several
times. If this fails, fill water
tank and use mains pressure
to pressurize tank
Water tank is empty Fill water tank
Kinked hose
Check hoses ensuring none
are fouled
Damaged / worn pump
diaphragm
Repair or replace pump
Gas
Problem Possible Cause Remedy
Cooker not igniting
Gas bottle empty Fill gas bottle
Gas bottle not turned on Turn on valve on gas bottle
Gas hose on cooker not
connected
Check bayonet is securely
connected into receiver
Regulator blocked
Check regulator is not
blocked with dirt, wasp nests
etc
Kinked hose
Check hose is not twisted and
kinked
• Remember that first use after connecting gas will take a little while for the gas to purge the
line to the cooktop. Hold the control knob down for up to 4 minutes